Equipment: Difference between revisions

mNo edit summary
mNo edit summary
Line 83: Line 83:
|}
|}


==Connection and Configuration==
==Configuration==
Some equipment has configurable behavior, for example [[loader]]s can be configured to unload.
 
Pertinent to the next section, the selected configuration can change the pipe connection types. This happens with [[Refinery|Refineries]] and [[Chemical Lab]]s for example. In this situation, the pipe connections aren't labeled until the equipment is powered, so it's recommended to select a recipe and power the equipment before connecting pipes.
 
==Connection==
[[File:Equipment power stages.png|thumb|200x200px]]
[[File:Equipment power stages.png|thumb|200x200px]]
Most equipment has [[cable]] and/or [[pipe]] connection points, which need to be connected after the equipment is installed for the equipment to function.
Most equipment has [[cable]] and/or [[pipe]] connection points, which need to be connected after the equipment is installed for the equipment to function.


===Power===
===Power===
Equipment that requires [[power]] has a light red hexagon shaped connection point. A [[cable]] carrying power should be run to this connection point.
Equipment that requires [[power]] has a light red hexagon shaped connection point. A [[cable]] carrying power should be run to this connection point.  
#When equipment is not receiving power, the equipment icon is darkened and a red lightning bolt flashes on it.
#When equipment is not receiving power, the equipment icon is darkened and a red lightning bolt flashes on it.
#When equipment is connected to power, it will begin powering up. During this time the equipment remains dark, but the flashing lightning bolt is replaced by a light red power bar that begins filling.
#When equipment is connected to power, it will begin powering up. During this time the equipment remains dark, but the flashing lightning bolt is replaced by a light red power bar that begins filling.
#Once the power bar fills, the equipment will be fully powered up, and the icon will lighten.
#Once the power bar fills, the equipment will be fully powered up, and the icon will lighten.


===Configuration===
===Pipes ===
Some equipment has configurable behavior, for example [[loader]]s can be configured to unload.
 
Pertinent to this section, the selected configuration can change the pipe connection types. This happens with [[Refinery|Refineries]] and [[Chemical Lab]]s for example. In this situation, the pipe connections aren't labeled until the equipment is powered, so it's recommended to select a recipe and power the equipment before connecting pipes.
 
===Pipes===
[[File:Equipment_pipe_connections.png|frameless]]
[[File:Equipment_pipe_connections.png|frameless]]


Pipe connections are circles that are color coded to match the fluid/gas.
Pipe connections are circles that are color coded to match the fluid/gas.  
*When not connected the circle is unfilled, has an arrow indicating the direction of flow, and displays text labelling the type.
*When not connected the circle is unfilled, has an arrow indicating the direction of flow, and displays text labelling the type.
*Once connected, the text and arrow disappear. If the connection is an input with nothing flowing, the circle will be unfilled, otherwise the circle will be filled.
*Once connected, the text and arrow disappear. If the connection is an input with nothing flowing, the circle will be unfilled, otherwise the circle will be filled.
*[[Tank]]s do not have a pre-defined type, nor a flow direction, so when empty and unconnected the circle will be a generic gray color and lack an arrow or text label.
*[[Tank]]s do not have a pre-defined type, nor a flow direction, so when empty and unconnected the circle will be a generic gray color and lack an arrow or text label.